Ground Stabilisation for a London Developer

Project Details
Client :
Developer
Category :
Ground Stabilisation
Location :
London
Date :
May 2021
Value :
£38,000.00
Ground Stabilisation for a London Developer - 2

Ground Stabilisation for a London Developer

The Developer had a requirement to increase the existing buildings height to create an apartment complex, however, due to the underlaying soils ground bearing capacity not being suitable, a  geopolymer solution was developed and designed in collaboration with the client’s structural engineer to facilitate the build. The required ground bearing capacity for ground was 100 KN/m2 which required materials to be blended and mixed to meet the required strength.

Ground Stabilisation for a London Developer - 1_500h
Ground Stabilisation for a London Developer - 3_500h

The works involved driving injection lances 2.5 meters below the perimeter foundations and internal foundations. Once installed, the injection lances were injected with a structural polyurethane ground stabilisation geopolymer resin. During the process the injection lances were extracted at 150mm increments to guarantee continuous placement of the geopolymer.